Protecting Measurement Accuracy and Analyzer Reliability

Instrumentation and analyzer systems depend on process samples and sensitive equipment remaining within required operating limits.

Excessive heat can cause sample fluids to vaporize, change viscosity, or reach analyzers at temperatures above their allowable range. Cold conditions can cause fluids to thicken or freeze in process lines, instruments, and enclosures. These thermal extremes can affect sample condition and measurement reliability, damage equipment, or take instrumentation offline.

Thermostatic valves respond directly to changing thermal conditions to regulate heating or cooling media or stop flow when temperatures move outside the required range, without external power or electronic controls.

Sample Conditioning and Analyzer Protection

Process sampling and sample conditioning systems may require both process analyzer cooling and over-temperature protection before the sample reaches downstream instrumentation.

Sample Cooler Temperature Control

Sample coolers reduce process fluid temperatures before they reach analyzers or other downstream instrumentation.

ThermOmegaTech® US/S-XR and TV/US-XR valves regulate cooling media flow into the sample cooler to help maintain the sample within the required range. This supports analyzers and instrumentation that require controlled sample conditions for proper analysis.

High-Temperature Sample Protection

If cooling water is lost or the primary sample cooler cannot provide sufficient cooling, an overheated sample can continue downstream to sensitive analyzers and instrumentation.

A thermal shutoff valve is commonly used after the sample cooler to provide an additional layer of protection. ThermOmegaTech® HST high temperature shutoff valve stops flow when the temperature exceeds the allowable set point, preventing overheated media from reaching downstream equipment.

Instrument Enclosures and Analyzer Shelters

Analyzer shelters, instrument cabinets, and insulated enclosures reduce exposure to weather and physical damage, but the equipment and sample lines inside can still be affected by freezing or excessive heat.

Freezing, vaporization, or changes in fluid viscosity can affect measurement accuracy and equipment operation. Instrument enclosure temperature control regulates heating or cooling media to keep the enclosure within its specified operating range.

Freeze Protection and Heating Control

Steam tracing is commonly used to heat instrument and analyzer enclosures in cold environments. However, uncontrolled steam flow can overheat the enclosure and affect the equipment or samples inside.

ThermOmegaTech® TV/SC-I valves mount through the enclosure wall and sense internal ambient conditions to regulate steam flow. For designs that keep the steam coil and valve connections inside the enclosure, TV/SC-A valves provide the same self-actuating control.

The ITCH Assembly provides an integrated option for applications requiring a complete steam-heating and enclosure control system.

Cooling Control for Instrument Enclosures

Instrument enclosures may also require cooling where ambient conditions, nearby process equipment, or internal heat loads cause the enclosure to overheat.

ThermOmegaTech® TV/SC-IR valves regulate water, glycol, air, or other cooling media as the enclosure heats up. Flow increases with cooling demand and decreases as the enclosure cools.

This self-actuating control helps maintain the required operating environment without a separate powered control loop.

Common Instrumentation and Analyzer Applications

These systems are used throughout power generation, chemical processing, refining, petrochemical processing, and other industrial facilities where temperature can affect sample condition, measurement reliability, or equipment operation.

Steam and Water Analysis Systems (SWAS)

Process Sampling and Sample Conditioning Systems

Process Analyzer Systems

Analyzer Shelters, Cabinets, and Instrument Enclosures

Instrumentation and Analyzer Products

Product Title Industry Application
US/S-XR Sample Cooler Temperature Control Valve Industrial Cooling Fluid Control
TV-US-X TV/US-XR Sample Cooler Temperature Control Valve with Tube Fittings Industrial Cooling Fluid Control
HST High Sample Temperature Shutoff Valve Industrial Cooling Fluid Control
TV/SC-A Ambient Sensing Steam Tracing Control Valve Industrial Freeze Protection
TV/SC-I Instrument Enclosure Temperature Control Valve Industrial Freeze Protection
ITCH Assembly | Instrument & Enclosure Temperature Control System Industrial Freeze Protection
TV/SC-IR Instrument Enclosure Cooling Control Valve Industrial Cooling Fluid Control
HAT Fluid Temperature Control Valve Industrial, Aerospace & Defense Freeze Protection, Galley Scald Protection
TV/HAT Fluid Temperature Control Valve with Tube Fittings Industrial, Aerospace & Defense Freeze Protection, Galley Scald Protection

Discuss Your Instrumentation or Analyzer Application

ThermOmegaTech® thermostatic valves provide automatic heating, cooling, and high-temperature shutoff for instrumentation and analyzer systems.

Need help determining the appropriate control method, media, set point, or installation configuration?